How does air conditioning work? A plain guide

By Editorial team. Updated 25 November 2026. Facts checked 15 November 2026.

Key takeaways

  • How does air conditioning work? An air conditioner does not make cold. It moves heat out of the room with a refrigerant that changes between liquid and gas, driven round a sealed loop by an electric compressor.
  • There are four main parts: a compressor, a condenser (the hot coil), an expansion valve and an evaporator (the cold coil). The cold coil takes heat from the room; the hot coil gives it to the outdoor air.
  • The heat has to leave the room. On a 2.5 kW Mitsubishi Electric split, our working puts about 3.0 kW of heat out of the outdoor unit at its rated cooling: the heat taken from the room plus the electricity the unit uses.
  • The room gets drier as it cools, because water in the air condenses on the cold coil and drains away.
  • A heat pump is the same machine run in reverse. Work on a split system’s refrigerant needs an F-gas qualified engineer.

The short answer: an air conditioner moves heat, it does not make cold

How does air conditioning work? It pumps heat from inside your home to outside. Penn State’s engineering course puts it plainly: the machine “moves unwanted heat from where you don’t want it (inside) to where it doesn’t matter as much (outside)”. The room feels cooler because heat has been taken out of it, not because cold has been put in.

The law uses the same idea. The energy labelling rules for Great Britain define an air conditioner as “a device capable of cooling or heating, or both, indoor air, using a vapour compression cycle driven by an electric compressor” (Regulation (EU) No 626/2011, Article 2). This guide explains that cycle part by part, then what changes between a split air conditioner, a portable air conditioner and the other types.

What the refrigerant does

The refrigerant is the fluid sealed inside the pipes. Daikin UK describes the whole process as revolving around “the refrigerant changing state between liquid and gas”. The refrigerant boils into a gas inside the room, taking in heat, and condenses back into a liquid outside, giving that heat out, over and over. Our air conditioning refrigerant guide covers the different gases.

The four parts and what each one does

The four steps follow Daikin UK’s explanation of the refrigerant cycle and Penn State’s course notes. Penn State places the compressor and the condenser coil in the outdoor unit and the evaporator coil in the indoor unit.

Compressor

The compressor “pumps the refrigerant around the system” (Daikin UK). Low-pressure gas goes in and comes out as a hot, high-pressure gas. Penn State notes that “the compressor needs energy to do the work of compressing the refrigerant”. In a split system it sits in the outdoor unit.

Condenser

At the condenser, Daikin UK says, the “high-temperature, high-pressure gas releases its heat into the surrounding air” and condenses into a high-pressure liquid. Penn State: “Heat transfers from refrigerant to outdoor air.” In a split system the condenser is in the outdoor unit, also called the condensing unit.

Expansion valve

The high-pressure liquid then passes through an expansion valve, sometimes called the metering device. Daikin UK says the pressure is reduced, so “the temperature drops below the temperature of the refrigerated space”, leaving a cold, low-pressure liquid. Penn State describes a small orifice where the pressure drops sharply and the refrigerant cools.

Evaporator

The cold liquid flows into the evaporator, the coil in the indoor unit. Room air is blown across it, the refrigerant “absorbs heat from the indoor air” (Daikin UK) and evaporates into a gas, and the cooled air goes back into the room. The gas then “flows back to the compressor where the cycle starts all over again”.

Where the heat goes: a worked example

The heat taken out of the room and the electricity the compressor uses both have to leave through the condenser. Neither Daikin nor Penn State puts that as a sum, so the figure below is our working, from the rule that energy is not lost, using one maker’s published figures.

The Mitsubishi Electric MSZ-LN25VG3, with its MUZ-LN25VG3 outdoor unit, is a wall-mounted split rated at 2.5 kW of cooling for a nominal power input of 485 W in cooling (Mitsubishi Electric UK product information sheet, February 2026).

  • Heat taken from the room: 2.5 kW.
  • Electricity used by the system: 0.485 kW.
  • Heat released by the outdoor unit: 2.5 + 0.485 = 2.985 kW, about 3.0 kW (our working).
  • Running at that input for an hour uses 0.485 kWh, which costs 0.485 x 26.32p = 12.8p.

That is why every air conditioner needs a way to get rid of its heat outdoors, and why its cooling figure (2.5 kW) is not the electricity it uses (0.485 kW).

The 485 W is the maker’s nominal cooling input at the standard test conditions. This unit is an inverter, which Mitsubishi rates from 1.0 to 3.5 kW of cooling, so it often draws less once the room is cool, and a figure from rated input is an upper estimate. The 26.32p per kWh is Ofgem’s Great Britain average unit rate under the price cap for 1 October to 31 December 2026 (Direct Debit, standard variable tariff); it carries no VAT (0%) for this period, and we rework the figure when the cap changes. In Northern Ireland, use the unit rate on your own bill. The standing charge is left out. See air conditioning running costs for seasonal figures.

Why the room gets drier as it cools

Penn State says that “moisture in the air condenses on the cold coil and drains away”, so the air going back into the room is cooled and dehumidified. Drying is a side effect of cooling, because the evaporator coil is colder than the room. If water appears where it should not, see air conditioner leaking water. Many units have a setting that favours drying over cooling: see dry mode on air conditioning.

What changes by type of air conditioner

Every type uses the same four parts. What changes is where they sit, and how the heat gets outside.

Split and multi split

A split system has an indoor unit holding the evaporator and an outdoor unit holding the compressor and condenser. The GB F-gas Regulation defines a single split system as “one outdoor unit and one indoor unit” linked by refrigerant piping and installed where it is used (Article 2). A multi split runs two or more indoor units from one outdoor unit. Because the hot coil is outside, no room air is blown out of the building.

Portable and window units

A portable air conditioner has all four parts in one box, so the hot coil is indoors and its heat leaves through a hose in the window. On a single-hose unit, the regulation says the air for the hot coil “is introduced from the space containing the unit and discharged outside this space”, so other air leaks into the room to replace it. See how portable air conditioners work. A window air conditioner is also a single box, fitted in the window itself.

Because a refrigerant air conditioner must send its heat outside the room, a product sold as an air conditioner with no hose and no outdoor part is, in our reading, likely to be an evaporative air cooler. Check the listing for a compressor and a refrigerant, and see portable air conditioners without a hose.

Ducted

In a ducted system the indoor unit is hidden in a ceiling void or loft and ducts carry the cooled air to one or more rooms; the outdoor unit works as for any split.

Where each part sits

Type Compressor and condenser Evaporator How the heat leaves Read next
Split (wall mounted) Outdoor unit Indoor unit Refrigerant pipes to the outdoor unit Split air conditioners
Multi split One outdoor unit Two or more indoor units Refrigerant pipes to the outdoor unit Multi split
Ducted Outdoor unit Hidden indoor unit with ducts Refrigerant pipes to the outdoor unit Ducted
Portable (single hose) In the box In the box Room air blown out through a hose How portables work
Window In the box In the box The box sits in the window Window units

For each type in more depth, see types of air conditioner. If you are choosing one to buy, start with our air conditioning unit guide.

What an inverter changes

An inverter does not change the cycle; it changes how hard the compressor works. Daikin UK says an inverter “controls the electric voltage, current and frequency of a device”, so the compressor’s speed can vary. A fixed-speed unit, Daikin says, runs its compressor “at full power” and it “repeatedly switches on and off”. The Mitsubishi example is rated from 1.0 to 3.5 kW of cooling against its nominal 2.5 kW: 40% of nominal at its lowest and 140% at its highest (our arithmetic).

The word “inverter” is not a measure of efficiency. The energy label’s seasonal figure counts the losses from on and off cycling “depending on the type of control” (Regulation 626/2011, Annex VII), so the SEER shows the effect. We quote no percentage saving for inverters, because none we found says what it is compared with. See inverter air conditioners.

What the efficiency figures mean: kW, BTU, EER, SEER, COP and SCOP

The definitions below are the GB energy labelling regulation’s (Regulation (EU) No 626/2011, Annex I), in plain words.

  • kW of cooling. The rate at which the unit takes heat out of the room; the regulation calls the figure the maker declares the “declared capacity” (Annex I, point 33). It is not the electricity the unit uses.
  • BTU and BTU per hour. A BTU (British thermal unit) is an amount of energy, about 1,055 joules. BTU per hour is a rate of cooling, and air conditioners are rated in BTU per hour even when a listing says only “BTU”. 1 kW is about 3,412 BTU per hour, so a 2.5 kW split is about 8,530 BTU per hour, and a “12,000 BTU” unit is about 3.52 kW (NIST conversion factors). See what BTU means and how many BTU do I need.
  • EER (energy efficiency ratio). The rated EER is the cooling capacity in kW “divided by the rated power input for cooling” in kW, at the standard rating conditions: one test point. For the Mitsubishi example, 2.5 / 0.485 = 5.15, the maker’s stated EER.
  • SEER (seasonal energy efficiency ratio). “The overall energy efficiency ratio of the unit, representative for the whole cooling season”: the reference annual cooling demand divided by the annual electricity used for cooling. Split systems are labelled on SEER; the Mitsubishi example’s is 10.5.
  • COP (coefficient of performance). The heating version of EER: heating capacity divided by rated power input for heating, at the standard rating conditions.
  • SCOP (seasonal coefficient of performance). The heating version of SEER, “representative for the whole designated heating season”. The Mitsubishi example’s is 5.2.

Two details matter when you compare labels. First, the test conditions differ by type: split systems are rated in cooling at 35C outside and 27C inside, single-duct portables at 35C on both sides (Regulation 626/2011, Annex VII, Table 2). Second, the regulation works SEER and SCOP out for what it calls “European seasonal conditions”, and the energy label applies 350 hours of cooling a year to air conditioners other than single-duct and double-duct units, which in a home means splits (Annex VII, Table 4). It does not apply those 350 hours to single-duct or double-duct portables; where we cost a portable over 350 hours, that is our standard summer (an assumption).

Which refrigerant is in your unit

Split systems such as the Mitsubishi example use R32. Of the 47 current portable air conditioners in our product files, 37 state R290, which is propane (counted on 15 November 2026; 4 state R454C, 1 R32 and 5 give no refrigerant). Refrigerants are compared by global warming potential (GWP), which the GB F-gas Regulation defines as a gas’s warming effect “relative to that of carbon dioxide”, over 100 years.

Refrigerant GWP Safety class F gas?
R32 675 (Annex I of the GB F-gas Regulation) A2L: “non-toxic but of lower flammability” Yes
R290 (propane) 3 (Annex IV of the GB F-gas Regulation) A3: “non-toxic but highly flammable” No

The safety classes are from F-Gas Register’s bulletin in ACR Journal (9 March 2026). The F-gas rules cover only the fluorinated gases listed in Annex I; propane appears only in Annex IV, so it is not an F gas.

In Great Britain, new single split air conditioners holding under 3 kg of refrigerant cannot use an F-gas with a GWP of 750 or more (from 1 January 2025), so R32 (GWP 675) is allowed. New movable room air conditioners, which the law defines as hermetically sealed units the user can move between rooms, cannot use an HFC with a GWP of 150 or more (Annex III). The bans are on placing new products on the market, and nothing in them requires a system already fitted to be removed. Northern Ireland follows the EU F-gas rules instead. See R32 refrigerant, R290 air conditioners and the F-gas regulations.

How the same machine heats

Daikin UK says that to understand a heat pump, you “simply apply this same four-step process in reverse”. The indoor coil becomes the hot one, so the unit takes heat from the outdoor air and releases it indoors. Mitsubishi Electric calls the MSZ-LN an “Inverter Heat Pump” and rates the 2.5 kW model at 3.2 kW of heating. A split used this way is an air-to-air heat pump: see how an air-to-air heat pump works and heat pump against air conditioner.

How it differs from a fan or an air cooler

A fan has no compressor or refrigerant, so it is not an air conditioner under the definition above: it moves air. An evaporative air cooler works another way. The government’s Energy Technology List says direct coolers pass air “directly through a water-saturated medium”, and that this “can lead to high humidity levels in the cooled air produced”. So a cooler adds moisture, where an air conditioner removes it. A cooler also falls outside the GB definition, which requires “a vapour compression cycle driven by an electric compressor”. The same definition does mention water: it includes appliances that use water for evaporation on the condenser, “provided that the device is also able to function without the use of additional water, using air only”. That proviso is about those water-using air conditioners, not a test every air conditioner has to pass. See air cooler against air conditioner and evaporative cooler against air conditioner.

Who should work on it

GOV.UK says you must have F-gas qualifications to “install new systems”, “service and maintain systems”, “check for leaks”, “recover gases” and “decommission and dispose of old systems”. A category 2 certificate covers installing, servicing and recovering refrigerant on systems with less than 3 kg of F gas; the Mitsubishi example holds 0.8 kg of R32. Companies working on systems operated by others must also be certified. Separately, Article 11(4) of the F-gas Regulation says that for “installation, servicing, maintenance or repair”, F gases “shall only be sold to and purchased by undertakings that hold the relevant certificates” (or that employ certified people), so a householder cannot legally buy refrigerant to top up a system. These are Great Britain’s rules; Northern Ireland follows the EU’s.

The qualification rules are for work on the refrigerant circuit. For R290 easy-fit split kits, one seller’s listing (Appliances Direct, for the electriQ Easy-Fit, recorded in our product file on 14 November 2026) says the unit “does not require installation by an F-Gas registered engineer”. The F-gas rules cover fluorinated gases only, and propane (R290) is not one, but we found no GOV.UK or HSE guidance on who may fit a propane system. Follow the maker’s instructions. In England, regulation 12(6A) of the Building Regulations 2010 says a person intending electrical work covered by Part P must give a building notice or apply for building control approval with full plans where the work “consists of” “the installation of a new circuit” (among other things). See what an air conditioning engineer does, and for offices and shops, how a HVAC system works.

More explainers in this guide

Frequently asked questions

Does air conditioning make cold air?

No. It takes heat and moisture out of the room air and blows the cooled air back in. Penn State describes it as moving heat from inside, where you do not want it, to outside.

Where does the heat go?

Out through the condenser, the hot coil: in a split system that is the outdoor unit, and in a portable the heat leaves through the hose. For a 2.5 kW Mitsubishi Electric split, our working puts about 3.0 kW of heat out of the outdoor unit at rated cooling.

Why does an air conditioner drip water?

Moisture in the room air condenses on the cold indoor coil and drains away. If water appears inside the room, see air conditioner leaking water.

Does a portable air conditioner work the same way?

Yes. It uses the same four parts in one box, so the heat leaves through a hose in the window. See how portable air conditioners work.

Is an air conditioner the same as a heat pump?

They use the same cycle. Daikin UK says a heat pump applies the same four steps in reverse, so it can heat as well as cool. See heat pump against air conditioner.

Can I top up or fix the refrigerant myself?

No, not on a split system that uses an F gas such as R32. GOV.UK says servicing, leak checks and recovering refrigerant need F-gas qualifications. Article 11(4) of the F-gas Regulation says F gas for installation, servicing, maintenance or repair may only be sold to certified businesses (or those employing certified people). See the F-gas regulations guide.

Sources

  1. Daikin UK: The refrigerant cycle: what is it? (checked 14 November 2026)
  2. Penn State EMS, EGEE 102: 10.4 How Air Conditioners Work (checked 14 November 2026)
  3. legislation.gov.uk: Regulation (EU) No 626/2011 as it applies in GB, Article 2 (definitions) (checked 15 November 2026)
  4. legislation.gov.uk: Regulation (EU) No 626/2011 as it applies in GB, Annex I (definitions for Annexes II to VIII) (checked 15 November 2026)
  5. legislation.gov.uk: Regulation (EU) No 626/2011 as it applies in GB, Annex VII (measurements and calculations) (checked 15 November 2026)
  6. Mitsubishi Electric UK: MSZ-LN R32 product information sheet, effective February 2026 (PDF) (checked 14 November 2026)
  7. Mitsubishi Electric UK: MSZ-LN R32 Inverter Heat Pump product page (checked 14 November 2026)
  8. Ofgem: Changes to energy price cap between 1 October and 31 December 2026 (checked 14 November 2026)
  9. Daikin UK: What is inverter technology? (checked 14 November 2026)
  10. Daikin UK: Inverter air conditioners (checked 14 November 2026)
  11. NIST: SP 811 Appendix B.9, conversion factors (checked 14 November 2026)
  12. legislation.gov.uk: Regulation (EU) No 517/2014 as it applies in GB, Article 2 (definitions) (checked 14 November 2026)
  13. legislation.gov.uk: Regulation (EU) No 517/2014 as it applies in GB, Annex I (GWP of F gases) (checked 15 November 2026)
  14. legislation.gov.uk: Regulation (EU) No 517/2014 as it applies in GB, Annex IV (GWP of other substances, including propane) (checked 14 November 2026)
  15. legislation.gov.uk: Regulation (EU) No 517/2014 as it applies in GB, Annex III (product bans) (checked 14 November 2026)
  16. ACR Journal (F-Gas Register bulletin): Flammable refrigerants in air conditioning and heat pump systems, 9 March 2026 (checked 14 November 2026)
  17. GOV.UK: Qualifications to work with F gas (updated 3 March 2026) (checked 14 November 2026)
  18. Energy Technology List (DESNZ): ETL and Eurovent certification collaboration, energy efficient evaporative air coolers (4 October 2024) (checked 14 November 2026)
  19. legislation.gov.uk: Regulation (EU) No 517/2014 as it applies in GB, Article 11 (restrictions on placing on the market) (checked 15 November 2026)
  20. legislation.gov.uk: The Building Regulations 2010, regulation 12 (England version) (checked 15 November 2026)
  21. Appliances Direct: electriQ Easy-Fit eIQ-9WMINV listing (checked 14 November 2026 in our product file; not re-opened on 15 November 2026)

Products on this page

  • Mitsubishi Electric

    MSZ-LN25VG3 (indoor) with MUZ-LN25VG3 (outdoor), 2.5 kW

    2.5 kW cooling · 42 dB · 485 W · 13p an hour

    No current UK price found

  • electriQ

    Easy-Fit 9000 BTU A+++ WiFi Smart Wall Mounted Split Air Conditioner with Heat Pump (eIQ-9WMINV)

    9,000 BTU · 720 W · 19p an hour · 26 m²

    £754.97 at Appliances Direct, checked 14 Nov 2026

    See it at Appliances Direct

Figures from the maker or retailer listing. Cost an hour is our own, at the price cap of 26.32p a kWh.